4.1          All tank containers and swap tanks require essential manufacturing and test data to be recorded on a data plate. This will be generally found on the rear of the tank but may be found attached to the side of one of the rear corner posts.

4.2          The plate shown in figure 4.11 is a typical tank data plate with the sections identified.

 

Figure 4.11 Typical tank data plate

Owner’s name and address

Manufacturers name, address and manufacturing serial number

Tank design details

Operation details

Pressures

Materials

Connections

Inspecting authority

Hydraulic test data

Timber content

CSC safety approval plate

Customs plate

4.3          The important sections are the CSC safety approval plate and the hydraulic test data. Every tank should be subjected to a pressure test every 30 months and a full hydraulic test every 5 years and the date of the test marked on the data plate.