Table 17

Type approval photometric requirements for front fog lamp

Element

Angular coordinates in deg.

Luminous intensity

in cd

To comply

vertical

horizontal

Point 1, 2

45°L, R

60°U

8.5∙10 1 max.

All points

Point 3, 4

30°L, R

40°U

Point 5, 6

60°L, R

30°U

Point 7, 10

40°L, R

20°U

Point 8, 9

15°L, R

20°U

Line 1

26°L to 26°R

8°U

1.30∙10 2 max.

All line

Line 2

26°L to 26°R

4°U

1.50∙10 2 max.

All line

Line 3

26°L to 26°R

2°U

2.45∙10 2 max.

All line

Line 4

26°L to 26°R

1°U

3.60∙10 2 max.

All line

Line 5

10°L to 10°R

4.85∙10 2 max.

All line

Line 6 a

from 5° inwards

to 10° outward

2.5°D

2.70∙10 3 min.

All line

Line 7 a

from 5° inwards

to 10° outward

6.0°D

<   50 per cent of max. on line 6

All line

Line 8L and R

22°L and 22°R

1.5°D to 3.5°D

1.10∙10 3 min.

One or more points

Line 9L and R

35°L and 35°R

1.5°D to 4.5°D

4.50∙10 2 min

One or more points

Zone D

10°L to 10°R

1.5°D to 3.5°D

1.20∙10 4 max.

Whole zone

Notes to Table 17

a In case of lamps constituting a matched pair ,   the half of the sum of the respective measured values from both lamps together does not apply to this element (see paragraph 1.5. of Annex 4) In case of lamps constituting a matched pair the half the sum do not apply to this element

 

5.5 .2.2. In case of front fog lamps constituting a matched pair corresponding to paragraph 3.3.2.4.3., at the request of the applicant, the specified requirements in Table 17 and Table 19 apply to half the sum of readings of the right-hand and left-hand side   front fog lamp.

 

 


 

Table 19

Conformity of production, photometric requirements for front fog lamp

Element

Angular coordinates in deg.

Luminous intensity in cd

To comply

Equivalent
20 per cent

Equivalent
30 per cent

Point 1, 2

45°L, R

60°U

1.15∙10 2 max.

1.30∙10 2 max.

All points

Point 3, 4

30°L, R

40°U

Point 5, 6

60°L, R

30°U

Point 7, 10

40°L, R

20°U

Point 8, 9

15°L, R

20°U

Line 1

26°L to 26°R

8°U

1.60∙10 2 max.

1.70∙10 2 max.

All line

Line 2

26°L to 26°R

4°U

1.80∙10 2 max.

1.95∙10 2 max.

All line

Line 3

26°L to 26°R

2°U

2.95∙10 2 max.

3.20∙10 2 max.

All line

Line 4

26°L to 26°R

1°U

4.35∙10 2 max.

4.70∙10 2 max.

All line

Line 5

10°L to 10°R

5.85∙10 2 max.

6.30∙10 2 max.

All line

Line 6 a

from 5° inwards

to 10° outward

2.5°D

2.16 ∙10 3 min.

1.89∙10 3 min.

All line

Line 8L and R

22°L and 22°R

1.5°D to 3.5°D

8.80∙10 2 min.

7.70∙10 2 min.

One or more points

Line 9L and R

35°L and 35°R

1.5°D to 4.5°D

3.60∙10 2 min.

3.15∙10 2 min.

One or more points

Zone D

10°L to 10°R

1.5°D to 3.5°D

1.44∙10 4 max.

1.56∙10 4 max.

Whole zone

Notes to Table 19

a In case of lamps constituting a matched pair ,   the half of the sum of the respective measured values from both lamps together does not apply to this element (see paragraph 1.5. of Annex 4) In case of lamps constituting a matched pair the half the sum do not apply to this element

 

6.2.1.1.3.1 In the light-distribution as specified in Table 19, single narrow spots or stripes inside the area including the measuring points   1 to   10 and line   1 or inside the area of line   1 and line   2 with not more than   2.10∙10 2   cd are allowed, if not extending beyond a conical angle of   2° aperture or a width of   1°. If multiple spots or stripes are present, they shall be separated by a minimum angle of   10°.

 

6.2.1.1.3. 1. 2. If the results of the test described above do not meet the requirements, the alignment of the front fog lamp may be changed according to the provisions in Annex 5, paragraph. 4.1.